SEND SMS
SEND EMAIL

VLT Micro Drive

Leading Service Provider of fc200 vlt aqua drive, fc51 vlt micro drive, fc300 vlt automation drive, fc360 vlt automation drive, fc100 vlt hvac drive and ahf 010 and ahf 005 advanced harmonic mitigation solutions from Mumbai.

FC200 VLT AQUA Drive

FC200 VLT AQUA Drive
  • FC200 VLT AQUA Drive
Get Best Quote

Service Details:

BrandDanfoss
Model NumberFC200
Weight6.5 kg
Supply Voltage380-480 V
Protection GradeIP20
Diameter68x130x205 mm
Power132-450 kW
Ramp times1 - 3600 sec.
Current range at analog output0/4 - 20 mA

The VLT® AQUA Drive is designed to provide the highest level of performance of AC-motor-driven water and wastewater applications. Featuring a wide range of powerful standard features, which can be expanded with performance-improving options, the drive is equally suited to both new and retrofit projects. The considerable daily load variation in water or wastewater treatment plants makes it economically feasible to introduce motor control on rotating equipment such as pumps and blowers. The new generation VLT AQUA Drive can realistically offer first-year cost savings of between 10–30% compared to traditional drive solutions. Its high lifetime availability and low energy consumption and maintenance costs provide you with the lowest cost of ownership. The quick and user-friendly setup of water and pump settings reduces installation time ensuring a fast route to maximum energy efficiency and motor control. By collecting the most important parameters in one place, the risk of incorrect configuration is reduced significantly.

 

Features:
  • Assets are protected thanks to specially designed software that prevents, for example, water hammering
  • Energy efficiency is maximized as a result of the drives control algorithms and design which focus on reducing heat loss
  • High energy savings related to air conditioning are ensured due to the unique back-channel-cooling concept that transfers 90% of heat away from the room
  • Electromagnetic interference and harmonic distortion are reduced thanks to the built-in, scalable RFI filter and integrated DC link chokes
  • Perfect system integration and adaptation to the application are possible due to freely programmable warnings and alerts
  • 3–8% energy savings are achieved as a result of Automatic Energy Optimization

 

Supply voltages and power range:

    • 1 x 200-240 V...1.1-22 kW
    • 1 x 380-480 V...7.5-37 kW
    • 3 x 200-240 V...0.25-45 kW
    • 3 x 380-480 V...0.37 kW – 1 MW
    • 3 x 525-600 V...0.75-90 kW
    • 3 x 525-690 V...1.1 kW – 1.4 MW
    Request
    Callback
    Yes! I am Interested

    FC51 VLT Micro Drive

    FC51 VLT Micro Drive
    • FC51 VLT Micro Drive
    Get Best Quote

    Service Details:

    BrandDanfoss
    Model NumberFC51
    Frequency50/60 Hz
    Supply Voltage1 x 200 - 240 V
    Ramp times0.05 - 3600 sec
    Programmable inputs5
    LogicPNP or NPN
    Pulse input frequency20 - 5000 Hz
    Current range at analog output0/4-20 mA

    Request
    Callback
    Yes! I am Interested
    View PDF

    FC300 VLT Automation Drive

    FC300 VLT Automation Drive
    • FC300 VLT Automation Drive
    Get Best Quote

    Service Details:

    BrandDanfoss
    IP RatingIP20, IP55, IP66
    Frequency50/60 Hz
    Weight47 kg
    Model NumberFC300
    Supply voltage200 - 240 V
    Harmonic disturbanceMeets EN 61000-3-12
    Ramp times0.02-3600 sec.
    Scan interval5 ms
    Max output current40 mA
    Maximum output frequency0 to 32 kHz

    Request
    Callback
    Yes! I am Interested
    View PDF

    FC360 VLT Automation Drive

    FC360 VLT Automation Drive
    • FC360 VLT Automation Drive
    Get Best Quote

    Service Details:

    BrandDanfoss
    Frequency50/60 Hz
    Model NumberFC360
    Supply voltage380 - 480 V
    Ramp times0.01 - 3600s
    Digital7 inputs, (2 can be confi gured as digital outputs)
    LogicPNP or NPN
    Analog inputs2
    Current range at analog output0/4 to 20mA

    Request
    Callback
    Yes! I am Interested
    View PDF

    FC100 VLT HVAC Drive

    FC100 VLT HVAC Drive
    • FC100 VLT HVAC Drive
    Get Best Quote

    Service Details:

    BrandDanfoss
    Model NumberFC100
    Frequency50/60 Hz
    Closed Loop0-132 Hz
    Supply Voltage200-240 V
    Ramp times1 - 3600 sec.
    Current range at analog output0/4 - 20 mA

    Request
    Callback
    Yes! I am Interested
    View PDF

    AHF 010 and AHF 005 Advanced Harmonic Mitigation Solutions

    AHF 010 and AHF 005 Advanced Harmonic Mitigation Solutions
    • AHF 010 and AHF 005 Advanced Harmonic Mitigation Solutions
    Get Best Quote

    Service Details:

    BrandDanfoss
    Efficiency0.98
    Frequency50 Hz
    Model NumberAHF 010 and AHF 005
    Line Voltage380 - 415 V AC
    Filter Current10A - 325A (For higher power modules can be paralleled)
    Enclosure degreeIP20
    Overload current160% for 60s
    Ambient temperature5 - 40 Deg C without derating